RG 399
Analisador de gás de fumo
Application
The flue gas analyser RG 399 is suitable for supervising exhaust and process gases that contain traces of corrosive gas and /or dust. The gas preparation before analysing, is achieved by way of a double-filter that is self-regenerating.
Fields of Application
- Supervision of flue gases
- Supervision of boiler installations
- Supervision of process and exhaust gases
- and many more
Features
- Various types of measurement sensor can be used
- Long service life of the measurement sensors is ensured by including a pre-cleaning of the test gas to remove any corrosive components
- Gas conditioning specific to the application by the use of various types of filter medium
- Automatic regeneration of the filter used
- Suction system, thus hot test gases can be monitored
- Integrated flow control
- Direct recognition of the warning status by way of a coloured LC-Display
- Menu-assisted operation via two keys
- Three alarm levels, independently adjustable from 5 to 100% of the measurement range
- Three floating alarm outputs for controlling external warning and control devices
- Floating fault contact
- Serial output RS 232 or RS 485
- 4-20 mA current interface
- Various designs of housing are available, for example, 19" rack system, wall-mounting housing
- High standard of service reliability
- Low current consumption
- Un-interruptible power supply (UPS) is available
Examples of measurable gases
Gas |
Formula |
Carbon dioxide |
CO2 |
Carbon monoxide |
CO |
Methane (natural gas) |
CH4 |
Oxygen |
O2 |
Hydrogen |
H2 |
Other gases on request
Technical Data
Detail applies to one control unit |
Sensors: |
Heat reaction sensor
Heat conductivity sensor
Chemical measurement cell
Infrared sensor |
Sensor input: |
1 two-wire or three-wire sensor |
Sensor supply: |
20 V DC / 200 mA |
Measurement range: |
CO: 0 -100 ppm
CO2: 0 - 20 Vol%
O2: 0 - 25 Vol% |
Measurement accuracy: |
<2 % bzw. <5 % f.s.d. (dependent on measurement principle) |
Ambient temperature: |
10 °C to +40 °C |
Influence of temperature: |
<2 % at ±20 °C change in temperature |
Installation: |
Panel or wall mounting |
Output signals: |
Current output 4-20 mA
Interface RS 232 or RS 485
3 Alarm relays
1 Fault relay |
Relay switch rating: |
230 V, 450 VA
other voltages by request |
Mains voltage supply: |
230 V, 50Hz
115 V, 60 Hz (optional) |
Power consumption: |
300 VA |
Dimensions (WxHxD): |
710 x 600 x 380 mm |
Weight: |
approx. 45 kg |
Accessories
Gas extraction with protective cover, test gas connection with fine dust filter, gas extraction pipe, special extraction probe, installation connection pieces, condensate collector with mounting plate, sampled gas cooler with single or double cooling system. Further accessories can be offered on request, according to the intended measurement task.