Applications: |
detection of combustible gases and vapours, toxic gases and oxygen, visualisation and transmission of the measuring values |
Measuring principle: |
catalytic combustion, Infrared absorbtion, electrochemical reaction |
Measuring ranges: |
0-100% LEL alkanes [methane…hexane], hydrogen, ethylene,
0-25 Vol % O2,
0-5000 ppm CO2,
0-50 ppm H2S,
0-5000 ppm R134a, multiple refrigerants
|
Field of application: |
on deck, engine rooms etc. |
Approvals: |
ATEX, IECEX, EN60079-29-1, EN50104, SIL, MED 2014/34/EU, DNVGL Class Approval |
Device type: |
GTR 210 MED |