Ados

Accessories

Gas Warning Systems

Alarm horn (small version)

Technical Data:
Housing: Shock-proof thermoplastic (ABS), light gray
Protection class: IP 33 (DIN 40050 / IEC 529)
Sound level: approx. 92 dB (A), 3.28 feet
Dimensions
(WxHxD):
a) 2.76 x 6.69 x 3.07 inch
b) 2.76 x 10.08 x 3.07 inch
Weight: approx. 0.44 lbs
Mains supply: 115 V / 60 Hz; 12 V AC
230 V / 50 Hz; 24 V AC
Power consumption: 2 W
Option: with integrated warning light

 

a)                        b)

 

 
warning light
(red or yellow)

Alarm horn (large version)

Alarm signal for damp rooms and external installation
Technical data:
Housing: Shock-proof thermoplastic (ABS), light gray
Protection class: IP 55 / IP 66 (DIN 40050 / IEC 529)
Sound level: approx. 110 dB (A), 1 m
Dimensions
(WxHxD):
5.83 x 14.02 x 5.98 inch
Weight: approx. 2.42 lbs
Mains supply: 12 V - 115 V, 60 Hz
12 V - 230 V, 50 Hz
Power consumption: 20 W

Alarm horn (Ex version)

Alarm signal for damp rooms and external installation
Technical Data:
Housing: PC (ABS)
Protection class: IP 55 (DIN 40050 / IEC 529)
Sound level: approx. 110 dB (A), 1 m
Dimensions: (WxHxD) 5.8 x 14 x 6 inch
Weight: approx. 2.75 lbs
Mains supply: 115 V - 120 V, 60 Hz
24 V - 230 V, 50 Hz
Power consumption: 22 W

 

Warning banner

Optical warning for inadmissibly high levels of gas concentration. Double-side black lettering on a yellow background. Other lettering available on request.
Technical data:
a)

Version single (3 x 15 W);
Mains supply = 115 V 60 Hz
Dimension (WxHxD):
IP 30 = 9.05 x 2.95 x 2.99 inch
IP 54 = 14.49 x 5.83 x 4.41 inch
IP 65 = 12.2 x 6.1 x 3.94 inch
also as LED-version (24 V)

b)

Version single (3 x 15 W)
or version with integrated emergency supply voltage (comprising accumulator, charger unit with discharge protection and flasher relay);
Mains supply: 115 V 60 Hz
Dimension (WxHxD): 39.4 x 8.1 x 3.9 inch
(2 lines)

c)

The same like number b)
Dimension (WxHxD): 51.2 x 10.2 x 3.9 inch
(3 lines)

d) LED-CO warning banner
with stand-by voltage supply
– without figure –
”DANGER – POISON GASES / SWITCH OFF MOTOR“
Appropriated fo pendant or wall mounting. Fitted with: flashing device, discharge protection with power reclosing lockout and switch-over electronics together with a maintenance free NimH-battery for 4,8 V; with double-sided black lettering on a yellow background. Flashing at least 1 hour in case of alarm, with 3.28 feet connection cable.
Mains supply: 90 V AC – 264 V AC, 2 W; protection class IP30;
Dimension (WxHxD) = 39.4 x 8.1 x 3.9 inch
e)

LED-CO warning banner (3 lines)
– without figure –
the same like number d)

”Danger – poison gases/Vacate the garage immediately/
Switch off motor when stationary“
Dimension (WxHxD) = 51.2 x 10.2 x 3.9 inch

f)

LED-CO warning banner
the same like number d)

– with pictograms – equivalent to:
”Leave the garage immediately. Switch off motor when stationary“.
Flashing at least 1 hour in case of alarm, with 3.28 feet connection cable.
Mains supply: 90 V AC – 264 V AC, 2 W; protection class IP 30;
Dimension (WxHxD) = 39.4 x 8.1 x 3.9 inch

All versions conform to garage regulations.

 


a)

b)
c)
d)
e)
f)
 

Side view of the LED CO warning banner

 

Rotating mirror lamp

Motor-driven rotating lamp for optical warning of inadmissibly high levels of gas concentration.
Technical data:
Housing: Plastic base, transparent yellow glass guard
Protecting class: IP 56; Optional mounting position
Mirror revs.: 160 r.p.m., continuous operation
Dimensions: Ø 5.98 x 8.46 inch
Mains supply: 115 V, 60 Hz or
230 V, 50 Hz
12 V=, 24 V
Power consumption: 40 / 45 W

Rotating mirror lamp

Pulsating lamp (flashlight) for optical warning of inadmissibly high levels of gas concentration
Technical data:
Housing: Plastic base, transparent yellow glass guard
Protection class: IP 54; optional mounting position
 Dimensions: Ø 4.25 x 5.24 inch
Mains supply: 115 V / 60 Hz
230 V / 50 Hz
12 V=; 24 V=
Power consumption: 5 W

Test gas bottle

- zero-point-gas: synthetic air
- N-Butane in synthetic air (calibration gas)
- for non-aggressive gases
- for hydrogen sulphide (in stainless steel)
Inhalt: 2.64 gal
Füldruck: min. 100 bar

Pressure reducer

Pressure reducer for connection to the test gas bottles
Inlet pressure: max. 200 bar
Output pressure: 0,1 bar – 3 bar
Material: Brass

Room probes

Gas extraction system–housing of shock-proof plastic. Exchangeable filter material.
Technical data:
Dimensions:

Ø 3.2 x 1.3 inch
Ø 5.9 x 1.3 inch

Version: Lateral connection – with hose connector or cutting ring couplings

Sampled gas extraction

Carborundum filter with protective cap,
gas sampling pipe with isolating valve and test gas valve.
Versions:

V 4 A material (1.4571)
a.) with insulation
b.) without insulation

Mains Stand-by supply unit

The unit provides all supplies for the warning systems (banners, alarm horns), in the case of a normal type of failure in the mains supply. The unit contains a maintenance- free battery, an inverter, a charger unit and mains supply monitoring.
Technical data:
Input: 115 V 60 Hz or 230 V 50 Hz;
4 A max.
Output: 115 V 60 Hz or 230 V 50 Hz
Power consumption: 700 W max. for 1,5 hours.
Maintenance-free
Dimensions
(WxHxD) :
16.9 x 18.9 x 8.3 inch
Construction conforms to garage regulations.

Mounting stubs with single flange

Mounting stubs with single flange for mounting the gas extraction pipe.
Versions:

- material V4A (1.4571)
- material St 37
- with single flange DN 50 / PN 6, 0.49 feet long

Mains stand-by supply unit USV

The unit provides all supplies for the warning systems (banners, alarm horns), in the case of a normal type of failure in the mains supply. The unit contains a maintenance-free battery, an inverter, a charger unit and mains supply monitoring.
Technical data:
Input: 115 V 60 Hz
Output: version A:
115 V 60 Hz, 500 VA
version B:
115 V 60 Hz, 1.000 VA
version C:
115 V 60 Hz, 2.000 VA
version D:
115 V 60 Hz, 6.000 VA
Dimensions (WxHxD): version A:
17.3 x 21.6 x 3.3 inch
version B:
17.3 x 10.4 x 15.9 inch
version C:
 17.3 x 17.3 x 25.6 inch
version D:
 17.3 x 17.3 x 26.8 inch

Heated extraction pipe

Technical Data:
Length:

3.28 … 328 feet

Operation temperature: 149 °F … 248 °F
Nominal width: 4 … 8
Nominal voltage: 230 V≈
Outer diameter: 1.65 inch
End caps: with pull relief and bend
protection in PA 6 or silicone
Outer protection: Ppolyamide 6 ring-spendle tube,
flame retardant, halogen-free
Temperatures: -104 °F … +302 °F,
temporary >302 °F
Optional accessory: temperature controller

Stand-by power supply UPS 2000

For uninterrupted operation of the ADOS units:
LON®-Center 2000, MWS 903, MWS 906 and GWA 2000. Compact housing with NiMH batteries, with on/off switch. Permanent discharge device and exhaustive discharge protection.
Technical data:
Voltage: 115 V 60 Hz
or 230 V 50 Hz (optional)
Power consumption: 18 VA
Protection class: IP 54
Dimensions
(WxHxD):
9.4 x 6.3 x 3.5 inch
Weight: 4.4 lbs

Protection housing V2A for gas transmitter

EMC and Water Protection Housing V2A for applications e.g. in tunnels
Version A – up to 2 gas transmitters
Compatible ADOS gas transmitters: ADOS 592 TOX and LCTR 903 (TGS, VQ, IR) including polyamide adapter and EMC interference filter CSEF
Number of ADOS
gas transmitters:
up to 2 units
Housing material: V2A stainless steel
Protection degree: corresponds to IP 65
Dimensions (WxHxD): 10.24 x 9.45 x 6.3 inch
Weight (including gas transmitters):

approx. 7.93 lbs

EMC and Water Protection Housing V2A for applications e.g. in tunnels
Version B – up to 4 gas transmitters
Compatible ADOS gas transmitters: ADOS 592 TOX and LCTR 903 (TGS, VQ, IR) including polyamide adapter and EMC interference filter CSEF
Number of ADOS
gas transmitters:
up to 4 units
Housing material: V2A stainless steel
Protection degree: corresponds to IP 65
Dimensions (WxHxD): 22.05 x 12.6 x 7.87 inch
Weight (including gas transmitters):

approx. 22.93 lbs

tunnel applications V2A protection housing

Protection housing V4A for GTR 210

Fields of Application: Harsh environments like onshore- and offshore-platforms, gas- and oil-pipelines are characterized by a high degree of background pollution
Compatible ADOS
gas transmitters:
ADOS GTR 210 EX
(TGS,VQ, IR, TOX, PID)
Number of ADOS
gas transmitters:
1 unit
Housing material: V4A stainless steel
ATEX: EX II 2 G (for applications up to ATEX-zone 1)
Protection degree: corresponds to IP 65
Dimensions (WxHxD): 10.23 x 13.38 x5.5 inch
Weight (including gas
transmitters):

approx. 12.34 lbs

  tunnel applications V2A protection housing