Ados

FlexADOS 914

Multi-channel gas sensor system
FlexADOS 914

Suitability

The multi-channel gas detector system FlexADOS 914 continuously monitors the ambient air and provides an early warning of harmful, explosive and non-flammable gases and vapours. Together with the GTR 210 gas transmitter family, FlexADOS 914 fulfils EN 50271:2011, achieves safety integrity level SIL1 and can be used for primary explosion protection.

Areas of application

  • Explosion protection chemicals industry
  • Paint and varnish manufacturing
  • Liquid gas storage facilities
  • Laboratories
  • Refrigerated warehouses (ammonia monitoring)
  • Refineries
  • Measurement of oxygen concentration
  • Gas-powered boilers
  • Wastewater treatment plants
  • and much more

Features

  • Up to 12 analogue 4...20mA sensors are evaluated (GTR 210, LCTR 903, TOX 592)
  • Graphic LCD display to show actual values, mean values and faults in plain text
  • Indicator for operation, malfunction, maintenance, power failure
  • Simple menu-guided setting of the device parameters using 6-part keyboard
  • Three alarm thresholds per sensor, independently adjustable from 10 to 90% of the measuring range
  • Averaging from 1 to 60 minutes possible
  • Maximum of 14 potential-free changeover contacts to control further warning and control facilities
  • Potential-free changeover contact for malfunction, maintenance and power failure
  • As an option: Building control system connection for data transfer (measuring value and state)
  • Plastic wall housing (IP 54)
  • High operating reliability
  • Low power consumption
  • Simple assembly
  • Uninterrupted electricity supply possible

Measuring ranges

Gas types can be
adjusted as desired,
Examples:
CH4 methane
H2 hydrogen
H2S hydrogen sulphide
CO2 carbon dioxide
physical unit
adjustable as desired,
Examples:
%LEL
ppm
VOL%

Technical data

Sensors analogue 4...20mA 12 sensors
in a 2- or 3-wire system
Power supply 115 V / 60 Hz
230 V / 50 Hz (optional)
24 V / DC (optional)
max. power consumption 60VA
Operating conditions -13°F ...+113°F
80kPa...120kPa
0%...95% rel. humidity
non-condensing
Protection class due to housing (DIN EN 60529) IP 54
Dimensions (WxHxD) 11,8 x 9,06 x 4,73 inch
Displays Graphic LCD display 128x64 px
Background red/green/yellow
LED power, malfunction,
power failure, maintenance
digital inputs 3
analogue outputs 2 x power output 4...20mA
max. burden 400 ohm
digital outputs 17 relays
per 1 relay
Malfunction, power failure,
maintenance
14 alarm relays
Potential-free change-over
contacts
Switching capacity max 250V / 8A
other interfaces USB
Universal FieldBus (option)
Weight approx. 3 lbs
Service life
Buffer battery clock
Service life
Parameter memory

> 10 years

> 20 years
Storage conditions max. 1 year
-13°F ...+113°F
80kPa...120kPa
0%...95% rel. humidity
non-condensing
Conformity
EC type-examination according to
EN60079-29-1
EN50104
EN45544-1
EN50271
EN50270
EX marking Ex II (2) G

Accessories

Horn, warning light, blinker lamp, recorder, emergency power unit UPS 2000-24V, gas cooler, gas inlet, and much more. Additional accessories are offered on request depending on the measuring task.

Universal FieldBus

Optional data interfaces for building management systems (BMS)

 

• LONWorks

• Modbus RTU

• Profibus

• ModBus TCP

• TCP/IP (Webserver)